Skip to content
JADE Learning
Menu
  • Continuing Education
    • Online Continuing Education
      • Alarm Continuing Education
      • Electrical Continuing Education
      • Electrical Inspector Continuing Education
    • Live Continuing Education
      • Connecticut Electrical
      • Iowa Electrical
      • North Carolina Electrical
      • On Site Technical Training
  • Photovoltaic Training
    • Login to PV Training
  • Exam Prep
    • About
    • Reviews
    • Free Trial
    • Login to Exam Prep
  • About
    • Connect
    • Blog
    • Testimonials
    • Meet The Team
    • Feedback
  • Help
    • Contact
    • Technical Support
    • FAQ
    • NEC State Adoptions
    • Is Your Electrical License Accepted by Other States?
Login For Returning Users

Preparing for the Wisconsin Electrical Journeyman Exam

To help you prepare for the Wisconsin Journeyman Electrician Exam, we’ve gathered some information on what you can expect on the exam — plus some tips to help you pass.

Read Article

Most Recent

  • How to Prepare for the Washington Electrical Exam

    Before you become a journey-level or master electrician in Washington, you must pass an exam. Here’s what you can expect on the exam and some tips to help you pass.

    Read Article
  • How Electricians Can Make Money Installing EV Charging Stations

    Tap into the growing demand for electric vehicle charging stations to increase your income and reach new customers as a licensed electrician.

    Read Article
  • 2023 NEC Section 210.8(B): GFCI Protection, Other Than Dwelling Units

    These are some updated code changes and exceptions in section 210.8(B), which covers GFCI rules for personnel, other than dwelling units.

    Read Article
  • The De-Centralized Central Station

    This blog discusses the sustainability of central alarm stations hiring remote workers and the pros and cons that come with remote vs. in-person work.

    Read Article

Recently in

Single Family Dwelling Calculation, Optional Method.

If you are preparing to take an electrical licensing exam, you will need to know how to calculate the feeder or service load for a single family dwelling. Refer to section 220.82(A)&(B) in the 2014 National Electrical Code (NEC). Here is a sample problem. Use the optional calculation to find […]

Read Article

Securing & Supporting Cables & Raceways Part Two | JADE Learning

The requirements for securing and supporting are similar in intent, but there are differences. Securing is done by installing a mechanical means of attachment to the cable and attaching it to a stationary structural member so the cable does not move. This will prevent the cable or conduit from becoming loose and pulling away from a box or fitting. Support requires a mechanical means to prevent the cable from sagging or drooping which may cause damage to the cable and create a hazard. A cable may remain loose while its support is maintained.

Read Article

Table 250.102(C)(1) Sizing Grounded Conductors, Bonding Conductors, and Bonding Jumpers

Supply-Side grounded and bonding conductors are sized from Table 250.102(C)(1) in the 2014 NEC. In earlier Codes, all these conductors, as well as the Grounding Electrode Conductor, were selected from Table 250.66. Table 250.102(C)(1) from the 2014 NEC. It is very helpful to have a separate Table for selecting the […]

Read Article

GFCI Protection for Health Care Receptacles

Most exam tables at the dentist or doctor’s office are not “patient sleeping beds”. A patient sleeping bed is usually found in a health care facility’s patient room rather than in an exam room. Typically, these beds have sheets and pillows, rather than paper covering over vinyl. In an exam […]

Read Article

Posts navigation

Previous page Page 1 Page 2

Passing Your Journeyman or Master Exam Starts Here.

JADE Learning’s Online Exam Preparation. Practice at Home. On Your Schedule.

Get Started
Jade Learning

Online Continuing Education Courses

  • Electrical Continuing Education
  • Alarm Continuing Education
  • Electrical Inspector Continuing Education
  • All Courses

In Person Continuing Education Courses

  • Connecticut In Class CE
  • Iowa In Class CE
  • North Carolina In Class CE
  • On-Site Training

Helpful Links

  • JADE Learning Blog
  • Installing PV Systems
  • Testimonials
  • State Reciprocity Details
  • FAQs
  • Reporting Information
  • Privacy Policy and Terms

Contact Us

  • Connect with Us
  • Phone: 1-800-443-5233
  • Email: registrar@jadelearning.com

© Copyright Certus. All Rights Reserved.

Certus logo

Login

Sign in with your username and password.

Forgot Your Password?

Don't wait for an Electrical Inspector to teach you the 2023 NEC. Save time, money, and pass inspections the first time by completing our online continuing education courses.

Sign up for your course and get started today!

Course On Phone