The 2020 National Electrical Code (NEC) has ushered in a brand-new method for determining the number of receptacle outlets required to serve island countertops; peninsular countertops; and work surfaces located in kitchens, pantries, breakfast rooms, dining rooms, and similar areas of a dwelling unit.
The method for measuring the countertop space for peninsulas has been changed for 2017. We know that NEC Section 210.52 requires that at least one receptacle be provided for each island or peninsula countertop that fits the dimensional requirements. The intent of the Code here is to discourage the use of extension cords. For example, countertop outlets must be spaced so that the typical two-foot extension cord can reach an outlet from any part of the countertop. Previously, the minimum distance triggering the outlet requirement was measured from the junction where the peninsula abutted the front edge of the perpendicular countertop, thus usually requiring an outlet mounted in the peninsular base cabinet. The new method of measurement begins at the wall behind the countertop.