2023 NEC Section 210.8(B): GFCI Protection, Other Than Dwelling Units

These are some updated code changes and exceptions in section 210.8(B), which covers GFCI rules for personnel, other than dwelling units.

Read Article

Most Recent

  • The De-Centralized Central Station

    This blog discusses the sustainability of central alarm stations hiring remote workers and the pros and cons that come with remote vs. in-person work.

    Read Article
  • Rethinking Business Security for the New Normal

    A new security study found that physical security incidents keep growing year over year, and businesses are struggling to keep up and stay secure.

    Read Article
  • 2023 NEC Section 210.8(A)(5): GFCI Protection for Basements

    Here are some important 2023 NEC changes made to 210.8(A)(5), which covers rules for GFCI outlets in basements.

    Read Article
  • 2023 NEC Section 210.8(A)(7): GFCI Protection for Areas with Sinks and Food Preparation

    Here are the 2023 NEC changes made to Section 210.8(A)(7), which covers rules for GFCI outlets near areas with sinks.

    Read Article

Recently in

Countertops Located in Other than Kitchen Areas – Section 210.52(A)(2) 2017 NEC

We are all familiar with the NEC requirement to place receptacles within the first 24 inches of a kitchen countertop edge, and then locate them every 48 inches thereafter. But did you know that fixed countertops in rooms such as dens, libraries, living rooms, bedrooms and the like now have receptacle requirements, and they are different from the requirements found in 210.52(C) that apply to kitchens?

Read Article

NEC 210.52(C)(3) New Peninsular Receptacle Requirements for the 2017 NEC

The method for measuring the countertop space for peninsulas has been changed for 2017. We know that NEC Section 210.52 requires that at least one receptacle be provided for each island or peninsula countertop that fits the dimensional requirements. The intent of the Code here is to discourage the use of extension cords. For example, countertop outlets must be spaced so that the typical two-foot extension cord can reach an outlet from any part of the countertop. Previously, the minimum distance triggering the outlet requirement was measured from the junction where the peninsula abutted the front edge of the perpendicular countertop, thus usually requiring an outlet mounted in the peninsular base cabinet. The new method of measurement begins at the wall behind the countertop.

Read Article

Measuring Kitchen Counter-top Space Behind Ranges, Cook-tops & Sinks. Figure 210.52(C)(1)

210.52(C) of the 2017 NEC lays out the requirements for kitchen countertops and the receptacles that are required to serve them. The countertop space located directly behind a range, counter-mounted cooking unit (such as a cooktop), or sink may or may not be counted as part of this measurable countertop surface when determining receptacle requirements and receptacle spacing for the countertop. It all depends on the depth of countertop surface behind that component.

Read Article

Passing Your Journeyman or Master Exam Starts Here.

JADE Learning’s Online Exam Preparation. Practice at Home. On Your Schedule.

Get Started
Jade Learning

Online Continuing Education Courses

  • Electrical Continuing Education
  • Alarm Continuing Education
  • Electrical Inspector Continuing Education
  • All Courses

In Person Continuing Education Courses

  • Connecticut In Class CE
  • Iowa In Class CE
  • North Carolina In Class CE
  • On-Site Training

Helpful Links

  • JADE Learning Blog
  • Installing PV Systems
  • Testimonials
  • State Reciprocity Details
  • FAQs
  • Privacy Policy and Terms

Contact Us

  • Connect with Us
  • Phone: 1-800-443-5233
  • Email: registrar@jadelearning.com

© Copyright Certus. All Rights Reserved.

Login

Sign in with your username and password.

Forgot Your Password?

Don't wait to let the Electrical Inspector teach you the new 2020 NEC. Save time, save money, and pass inspections the first time with the NEC Challenge.

Learn 156 of the most important 2020 NEC changes by having Code-based Q&A delivered by text or email three times a week.

Learn More
Image