The method for measuring the countertop space for peninsulas has been changed for 2017. We know that NEC Section 210.52 requires that at least one receptacle be provided for each island or peninsula countertop that fits the dimensional requirements. The intent of the Code here is to discourage the use of extension cords. For example, countertop outlets must be spaced so that the typical two-foot extension cord can reach an outlet from any part of the countertop. Previously, the minimum distance triggering the outlet requirement was measured from the junction where the peninsula abutted the front edge of the perpendicular countertop, thus usually requiring an outlet mounted in the peninsular base cabinet. The new method of measurement begins at the wall behind the countertop.
210.52(C) of the 2017 NEC lays out the requirements for kitchen countertops and the receptacles that are required to serve them. The countertop space located directly behind a range, counter-mounted cooking unit (such as a cooktop), or sink may or may not be counted as part of this measurable countertop surface when determining receptacle requirements and receptacle spacing for the countertop. It all depends on the depth of countertop surface behind that component.