Bathroom branch circuit requirements have changed for the 2020 Code cycle. The one 20-amp branch circuit traditionally required by NEC Section 210.11(C)(3) to feed only receptacles in dwelling unit bathroom(s) is now restricted to feeding only countertop receptacles in those same bathroom(s).
The receptacles permitted on this newly defined branch circuit include any countertop receptacles required to be within 3 feet of the bathroom’s sink basin and any other receptacle(s) installed to serve countertops or similar work surfaces in these bathroom(s).
The 2020 Code Making Panel (CMP) has revised the 2017 NEC rules regarding receptacles serving dwelling unit balconies, decks, and porches – specifically, the requirement that an accessible outdoor receptacle must be installed to serve attached balconies, decks, and porches. The revised Code now requires that a receptacle be installed to serve the balcony, deck, or porch when the balcony, deck, or porch is within 4 inches of the dwelling unit. If the balcony, deck, or porch is within 4 inches of the dwelling, the 2020 NEC considers that close enough so that it now requires a general use 120-volt receptacle.